Below is the quick text version of the timer set-up for the LAE TMR 15 that we use in the Vacuum Heat Press

The full PDF is Here ( click to view, right click as save target to download )

TMR15

The TMR15 features two main operating modes: Normal and Manual; when the unit is powered, its software loads the operating mode active before the TMR15 was switched off.

2. Operating Modes

    1. Normal Mode. In the STOP state, the output is off and the display shows the programmed cycle time. Pressing the button rotate right or making the remote start contact causes the output to be switched on and the display shows the countdown time. During the countdown, by pressing the buttons (t) or (u), the total cycle time is displayed. By pressing rotate right it’s possible to quit the program and switch over to the STOP state at any time. In case of a power failure, the timer always resumes the STOP state.
    1. Manual Mode. Pressing the button (stop) for 3 seconds activates the manual mode, with the buttons (t) and (u) you choose the permanent state of the output ( On / Off ). This operating mode and the associated state are stored and maintained even in the case of power failure. To exit and revert to normal mode, press () for 3 seconds.
    1. Cycle Time Setting. From the STOP state it’s possible to program the time by pressing (t) or (u) until you obtain the desired value. Auto scaling in minutes, seconds and hours takes place automatically, the respective two dots on the display show the scale active, in other words: 9 minutes and 59 seconds and 9 hours and 99 minutes. Exit from the programming is automatic after 5 seconds of not using the keypad or immediate by pressing (stop).
    2. Setup. The setup is accessed by pressing and keeping the buttons (stop) + ( rotate right ) pressed for 5 seconds. The available parameters appear in the table here below. Press button (u) to pass from one parameter to the next, vice versa, press the button (t) to go back. To display the value of a parameter press (rotate right), to modify it press (rotate right) + (t) or (u) simultaneously. Exit from the set up is either by pressing (stop) or automatic after 20 seconds of not using the keypad.

Par.

Adjustment

Description

Air

YES/NO

Buzzer enabling

Loc

YES/NO

Keypad lock

Adr

1..255

Peripheral Address